Can wearing a continuous glucose monitor (CGM) help protect your kidneys? A large American study published in JAMA Network Open tracked adults with poorly controlled type 2 diabetes for up to three years, comparing those who began using a real-time CGM with similar people who did not. Sensor users kept a lower HbA1c throughout and, by year three, had less albumin in their urine. Their kidney filtration, however, was no better. This article explains the findings, what the study cannot prove, how CGM is offered on the NHS, and which results from your diabetes annual review are worth keeping an eye on.
What the researchers found
The study appeared in JAMA Network Open in October 2026 and was summarised by News-Medical. Its authors drew on electronic health records from Kaiser Permanente Northern California, a large US healthcare provider. They compared 2,771 adults who started a real-time CGM, a small sensor worn on the skin that estimates glucose every few minutes, with 22,877 similar adults who did not. Everyone had type 2 diabetes with poor glycaemic control, and follow-up lasted up to 36 months.
HbA1c stayed lower throughout
HbA1c (called A1C in the US) shows your average blood sugar over roughly the past three months. UK laboratories report it in mmol/mol, while the study used percentages. Compared with non-users, sensor users were about 12 mmol/mol (1.10 percentage points) lower after one year, about 10 mmol/mol (0.90 points) lower after two years and about 8 mmol/mol (0.75 points) lower after three years. At the three-year mark that meant roughly 62 mmol/mol (7.83%) against 70 mmol/mol (8.58%). The advantage shrank over time but never vanished.
Urine albumin: a difference that appeared late
Albuminuria means that albumin, a protein normally kept in the blood, is leaking into the urine. It is one of the earliest signs that the kidneys are under strain, and it is measured with the urine albumin-to-creatinine ratio (ACR). The two groups did not differ at the start, after one year or after two years. At three years, the ratio averaged about 153 mg/g in sensor users and 278 mg/g in the comparison group, which is roughly 17 mg/mmol against 31 mg/mmol in the units used by UK laboratories. That three-year analysis was based on only 331 sensor users and 3,890 comparison participants.
No clear benefit for eGFR
The estimated glomerular filtration rate (eGFR) is calculated from a creatinine blood test and indicates how well your kidneys are filtering. Sensor users began the study with a lower eGFR, and by three years the gap was no longer statistically significant. The authors found no evidence that using a sensor preserved kidney filtration.
| Test | What it measures | Finding in the study |
|---|---|---|
| HbA1c (mmol/mol) | Average blood glucose over about three months | Lower in sensor users at one, two and three years |
| Urine ACR (mg/mmol) | Albumin leaking into the urine, an early kidney warning sign | No difference until year three, then lower in sensor users (small subgroup) |
| eGFR | How well the kidneys filter the blood | No sign that filtration was protected |
Why the study does not show that sensors protect the kidneys
The authors are clear that their work does not demonstrate that a CGM stops kidney disease from progressing. Anyone reading the headlines should bear several caveats in mind.
- This was an observational study. People who choose a sensor may be more motivated or better supported, or have better access to care, than people who do not, even after statistical adjustment.
- Many people switched groups: 44.3% of sensor users stopped using the device and were censored, while 18.7% of the comparison group began using one.
- The three-year kidney analysis involved far fewer people than the full cohort, so the albuminuria finding is less certain.
- Continued sensor use was inferred from supply records rather than measured, and the results apply to real-time sensors only, not to scanned (flash) systems.
- Dexcom was one of the funders, although the authors state that the funders played no part in the design, analysis or decision to publish.
- The study took place within a US health system, so its patients and care pathways differ from those of the NHS.
Latest scientific advances
Two other 2026 papers, retrieved from PubMed, help to put the study in perspective. In a small retrospective study of people newly diagnosed with type 2 diabetes, larger blood sugar spikes after meals, recorded over two weeks of sensor wear, were linked to a greater rise in urine albumin over six months, independently of HbA1c and fasting glucose. In other words, two people can share a similar HbA1c yet have very different after-meal peaks, and those peaks may tell us something extra about the kidneys. The authors say the finding needs independent confirmation before it is used in practice.
A systematic review of observational studies found that spending more of the day within the target glucose range, known as time in range, was associated with lower risks of death and of several complications, including damage to the eyes and nerves. The link with albuminuria, however, was not statistically significant in the main analysis. The practical message: sensor data may come to complement HbA1c, but it has not replaced your kidney tests.
What this means for you in the UK
Who can get a CGM on the NHS
NICE guidance on type 2 diabetes (NG28) recommends offering intermittently scanned CGM, often called flash monitoring, to adults on multiple daily insulin injections who have recurrent or severe hypoglycaemia, impaired awareness of hypos, a condition or disability that prevents finger-prick testing, or who would otherwise need to test at least eight times a day. It should also be offered to adults on insulin who would otherwise need a carer or health professional to check their glucose. Real-time CGM, the type used in this study, can be considered instead if it is available at the same or lower cost. Most people with type 2 diabetes who are not on insulin will not be eligible on the NHS, and the study does not change that guidance.
Read HbA1c and sensor data side by side
An HbA1c result is a three-month average, whereas a sensor reveals day-to-day patterns, including after-meal spikes and night-time lows. If the two do not seem to agree, take both to your diabetes review. NICE generally supports an HbA1c target of 48 mmol/mol (6.5%) for people managed with lifestyle or medicines that do not cause hypos, and 53 mmol/mol (7.0%) for those on medicines that can cause hypoglycaemia, although your target should be agreed with you. Our guide to HbA1c normal range and target levels explains how results are graded.
Make sure your kidney tests happen every year
Early diabetic kidney disease usually causes no symptoms, so it is picked up by testing. The NHS says people with type 2 diabetes should have their kidneys checked at least once a year as part of routine care, alongside an HbA1c test every 3 to 6 months. NICE recommends using both an eGFR blood test and a urine ACR, and regards a confirmed ACR of 3 mg/mmol or more as clinically important. You can read how the urine test works in our explanation of the microalbuminuria urine test, and how filtration is estimated in our overview of the eGFR kidney filtration rate.
Know what a sensor can and cannot do
Sensor readings are estimates of glucose in the fluid under the skin, not in the blood. NICE advises that people using CGM will still need occasional finger-prick tests, for example to check the device's accuracy. Sensors also have to be replaced every 7 to 14 days. If you have diabetes treated with medication, you are entitled to a medical exemption certificate for free NHS prescriptions in England, and prescriptions are free in Scotland, Wales and Northern Ireland. For the wider picture, see our complete guide to diabetes causes, symptoms and treatments.
When to speak to your GP or diabetes team
- Your HbA1c stays above the target you agreed, despite treatment.
- Your latest urine ACR or eGFR has changed since the previous result.
- You notice foamy urine, swollen feet, ankles or hands, or unusual tiredness.
- You have not had a kidney check in the past 12 months.
- You would like to know whether you meet the NICE criteria for a CGM, or whether one would suit your treatment.
Do not change or stop any medicine on the strength of a news story.
Glossary
- HbA1c (A1C): a blood test reflecting your average blood glucose over about three months, reported in mmol/mol in the UK.
- Albuminuria: albumin, a blood protein, appearing in the urine, often an early sign of kidney damage.
- Continuous glucose monitor (CGM): a wearable sensor that estimates glucose in the fluid under the skin every few minutes. Flash (isCGM) devices are scanned; real-time (rtCGM) devices send readings automatically.
- eGFR: an estimate of how well the kidneys filter the blood, worked out from a creatinine blood test.
- Urine ACR: the albumin-to-creatinine ratio in a urine sample, reported in mg/mmol in the UK.
- Time in range: the proportion of the day your glucose stays within a target band.
FAQ
Will a continuous glucose monitor protect my kidneys?
This study cannot answer that. Sensor users had a lower HbA1c and, later on, less urine albumin, but their kidney filtration was not better, and the study was observational.
Can a CGM replace my HbA1c test?
No. They measure different things and are normally used together.
Which kidney tests should I have with diabetes?
Usually a blood test for eGFR and a urine ACR test, at least once a year according to the NHS. See our guide to the kidney function panel for what each result means.
Who took part in the study?
Adults with type 2 diabetes and poor glycaemic control who had never used a sensor, with an average age of around 61, all treated within a US healthcare system.
Sources
- News-Medical, 12 October 2026: summary of Karter et al., JAMA Network Open, 2026
- Yu T. Postprandial hyperglycaemic area from continuous glucose monitoring and change in urinary albumin-to-creatinine ratio. Frontiers in Endocrinology, 2026
- Qu F et al. Time in Range and Adverse Outcomes in Type 2 Diabetes: A Quantitative Synthesis. Journal of Clinical Medicine, 2026
- NICE guideline NG28: Type 2 diabetes in adults, management
- NICE guideline NG203: Chronic kidney disease, assessment and management
- NHS: Type 2 diabetes, treatment and check-ups
- NHS Business Services Authority: Medical exemption certificates
- NIDDK (NIH): Continuous Glucose Monitoring